Electrical System
Conveyor Electrical System
Electrical System
Conveyor Electrical System
¾At the end of a cook cycle, the Controller outputs a 24 VAC
signal to a solid state relay which closes.
¾The output of the solid state relay allows 120 VAC to reach
the conveyor motor and start capacitor.
¾The Controller ceases to output the 24 VAC signal after the
cook chain has rotated a ½
of a revolution.