¾The Controller initiates a call for ignition of the lower burner.
(A separate LED dot can be seen at the top of the Controller
display)
¾The Controller supplies a 24VAC signal to the lower ignition
module.
¾The lower ignition module supplies a 24VAC signal to the
lower gas valve solenoid which allows the gas valve to open.
¾The lower ignition module then supplies a high voltage to the
igniter to produce spark.
¾Gas mixes with air present at the lower air burner shutter.
¾ Spark is present at the igniter and ignition occurs.