Troubleshooting
Step 3 Components
Troubleshooting
Step 3 Components
Upper Gas Valve
Input Voltage Check
24 VAC across each solenoid from lower
ignition module
Output Voltage Check
Test pressure tap for open valve
with manometer
Blower Motor
Input Voltage Check
120 VAC across
motor leads
Output Voltage Check
Running motor
Resistance Check
-Approx 22.2 ohms
Blower Motor Relay
Input Voltage Check
24 VDC across wires 30 & 32
from controller
Output Voltage Check
120 VAC across wires 4&6
Other Relay Tests
-With 24 VDC input there should be 120 VAC across the output
-With 0 VDC input there should be approx. 0 VAC across output