Troubleshooting
Step 7 Components
Troubleshooting
Step 7 Components
Conveyor Motor
Input Voltage Test
120 VAC across
motor leads
Output Voltage Test
With motor free from
drive chain motor
should run
Resistance Checks
Approx. Readings:
Black-Orange = 24.2 ohms
Black-Brown = 24.2 ohms
Orange-Brown = 49.2 ohms
Other Tests
:
Continuity from the motor lead to motor casing would
indicate a shorted winding